Lithium Batteries for Critical Infrastructure

Argentine manufacturer of high-capacity battery banks for servers, factories, and industrial backup systems. Technical specifications, performance curves, and quotes for corporate projects.

STP-4800
Lithium Battery Bank

48V / 100Ah · Integrated BMS · 6000 cycles

STP-Mod
Modular System

10–200 kWh · Redundant CAN bus

STP-CC200
MPPT Controller

Predictive charging · 12–48 V

Technical value for critical infrastructure

Measurable performance, direct integration, and engineering support

6000 cycles at 80% DoD

Industrial-grade LiFePO4 cells with integrated BMS. Projected lifespan exceeding 15 years in server backup applications.

Scalable modular architecture

Each 5kWh module connects in parallel without reconfiguring the system. Scale from 10kWh to 200kWh according to your plant's demand.

Real-time remote monitoring

Modbus and SNMP protocol for integration with infrastructure management systems. Historical data up to 90 days on touch screen.

Active thermal management

Temperature control system that keeps cells in optimal range even in extreme factory or server room conditions.

Adaptive MPPT algorithm

The STP-CC200 controller learns the installation's consumption patterns and prioritizes the most efficient source: solar, grid, or generator.

Technical Capabilities

Functions and services oriented to critical infrastructure

Real-time Remote Monitoring

Access to voltage, temperature, and current curves per module via Modbus TCP and SNMP. Historical data up to 90 days for performance analysis.

Modular Scalability Without Interruption

Each 5kWh module connects in parallel without reconfiguring the system. Expansion from 10 to 200 kWh without stopping active load.

Predictive Load Management

Adaptive MPPT algorithm that learns consumption patterns and prioritizes the most efficient source among solar, grid, or generator.

BMS with Multi-layer Protection

Active cell balancing, overcurrent and temperature cutoff. Industrial-grade LiFePO4 with over 6000 cycles at 80% DoD.

Installation Manuals for Engineers

Connection diagrams, torque specifications, and startup protocols. Downloadable technical documentation per project.

Technical Quotation per Project

Budget with estimated performance curves, bank sizing, and backup time according to the client's critical load.

Priority Technical Access

Receive performance curves, installation manuals, and quotes for corporate projects directly in your inbox.

You will receive the technical datasheets and conditions for your project within 24 business hours.

Frequently asked questions about industrial batteries

Technical answers for engineers and energy infrastructure managers.

Our STP-4800 banks with LiFePO4 cells exceed 6000 cycles at 80% depth of discharge. Under controlled temperature and charge conditions, service life can be extended up to 10 years before reaching 70% residual capacity.

The integrated BMS supports communication via Modbus RTU/TCP and SNMP. It can connect directly to programmable logic controllers (PLCs) or infrastructure management platforms such as Nlyte or Schneider EcoStruxure. No additional gateway is required.

Operating range: -10 °C to 50 °C with relative humidity up to 95% non-condensing. The internal thermal management system keeps cells between 15 °C and 35 °C. For outdoor installations, we recommend the optional climate-controlled cabinet.

Once we receive the critical load data, required autonomy, and installation conditions, we issue the technical quote within 48 to 72 business hours. For projects exceeding 100 kWh, an engineering review is included at no additional cost.

Yes. We include a 4-hour remote training session with each installation. We also offer on-site courses at our Buenos Aires facilities on diagnostics, predictive maintenance, and module replacement. The content is tailored to the technical team's profile.
Cookie settings

We use cookies to keep the site stable, remember basic preferences, and understand which pages are useful. You can accept, reject, or review the settings before continuing.